Operational Data
Temperature (min.)
|
-250
°C
|
Temperature (max.)
|
600
°C
|
Pressure (max)
|
250
bar
|
Gasket Characteristics DIN 2505 V
K0×Kd [N/mm]
|
50 × bd
|
k1 [mm]
|
1,3 × bd
|
Gasket Characteristics DIN 28090
бVO [N/mm²]
|
250
|
бVU 0,1 [N/mm²]
|
50
|
m
|
1.3
|
бBO 300 °C [N/mm²]
|
200
|
Gasket Characteristics ASME
Approvals and Test Reports
TA Luft 2002 (VDI 24A0/2200)
|
BAM oxygen
|
BAM oxygen (liquid)
|
Gas (DIN 3535-6)
|
EG 1935/2004
|
General information: All information given in this Technical Information sheet represents our current level of knowledge and serves as information on our products and their respective scopes. It is not meant to ensure any particular properties of any product or the suitability of any product for any specific application, neither does it create any liability on our part.
Last Changed 2023-09-29 20:05:13